pressure gauges ultrahigh-purity and clean dry air

Swagelok® Pressure Gauges, Ultrahigh-Purity and Clean Dry Air (PGU and PGC Series)

Swagelok® ultrahigh-purity and clean dry air pressure gauges use a Bourdon tube to reliably monitor positive system pressure and vacuum.

Request Pressure Gauge Information

Swagelok® PGU series ultrahigh-purity pressure gauges and Swagelok® PGC series clean dry air pressure gauges are designed for use in a wide range of applications, from bulk gas distribution to process tool applications. Their accuracy is in accordance with ASME B40.1, EN837-1, and JIS B7505.

PGU series gauges are ultrahigh-purity (UHP) “clean” for semiconductor gas applications in accordance with SEMI/SEMATECH, are cleaned and packaged in a class 100/10 cleanroom, and have 316L VAR end connections. PGC series gauges are assembled, cleaned, and packaged in a class 100 cleanroom and have 1/4 in. NPT end connections. Both series are purged with nitrogen and include protective cap over threaded connection. Every ultrahigh-purity and clean dry air gauge is 100% factory calibrated and helium leak tested to a maximum rate of 1× 10-9 std cm3/s.

Specifications

Dial Ranges PGU series: Vacuum to 3000 psi; 200 bar; 21 MPa
PGC series: Vacuum to 6000 psi; 400 bar; 40 MPa
Dial Sizes 28, 40, and 50 mm (1, 1 1/2, and 2 in.)
Accuracy
  • 50 mm (2 in.), ± 2% / 1% / 2% of span (ASME B40.1, Grade A, EN 837-1 Class 2.5, JIS B7505 Class 2.5)
  • 40 mm (1 1/2 in.), ± 3% / 2% / 3% of span (ASME B40.1, Grade B, EN 837-1 Class 4, JIS B7505 Class 4)
  • 28 mm (1 in.), ± 3% of span
Temperature Range Ambient: –40 to 140°F (–40 to 60°C)
Media: –40 to 212°F (–40 to 100°C)
End Connections PGU series: 1/4 in. female VCR® fitting, 1/4 in. rotatable male VCR fitting, 1/4 in. integral male VCR fitting, 1 1/2 in. flow-through surface-mount
PGC series: 1/4 in. male NPT fitting

Get Started with a System Evaluation

Pressure Gauges Catalogs

Locate detailed product information, including materials of construction, pressure and temperature ratings, options, and accessories.

A Swagelok pre-engineered subsystem

Small Footprint, Large Impact: How to Detect and Protect Against Gauge Failures

Learn to recognize the signs of a failing gauge and avoid risk to employees and costly downtime to make repairs.

Learn to Prevent Gauge Failure

Swagelok Resources Curated for You

A Swagelok tube fitting is installed
Common Causes and Costs of Fluid System Leaks

Fluid system leaks are a common occurrence in most plants. Learn how and why leaks occur, how to locate and test for them, and ultimately how to develop a strategy to address and reduce leaks plantwide.

希釈冷凍機メーカーであるブルーフォース社が、流体システム部品やソリューションに関して、スウェージロックに信頼を寄せている理由
最先端科学で信頼できる流体システム・ソリューション

フィンランドの希釈冷凍機メーカーであるブルーフォース社が、量子コンピューターや実験物理学などに欠かせない流体システム部品やソリューションに関して、スウェージロックに信頼を寄せている理由を紹介します。

カスタム・アセンブリーの小口径流体システムを検査するエンジニア
人手不足を緩和する流体システム製造

プラントにおける安定的なオペレーションは、さまざまな流体システムによって支えられています。人材が不足している場合、製造を外部委託することで状況を大きく改善できるかもしれません。

플랜트에서 작업자들이 공정 측정에 대해 논의하는 모습
공정 측정 – 임펄스 라인 모범 사례

공정 계장 애플리케이션에서 발생하는 문제는 전달 체계(transmitter)에만 집중해서는 파악하기 어렵습니다. Swagelok의 모범 사례와 팁을 통해 공정 계장 라인의 문제를 해결하는 방법에 대해 알아보십시오.

Этот процесс может занять несколько минут. Дождитесь его завершения и не покидайте страницу.